A must have utility for electrician's, electrical contractors or those looking to pass an electrical certification.
Calculations per National Electric Code 2014.
Calculations included:
Voltage Drop
-Circuit’s Conductors voltage drop.
-Minimum Conductor Size.
Pipe Bend
-Offset.
-Three bend saddles.
-Rolling Offset
-Detail Conduit Support.
-Segment bending.
Raceway calculations.
-Raceway size calculation.
-Raceway calculation
-Maximum number of same size wires
-Conduit Support\n-Conductors Support
-Conduit spacing
-Conductor Applications and Insulations
-Cable Tray Calculation
-Metric Trade Size Designators.
-R90, RW75, TWN75,T90, TW, TW75, TWU, TWU75
Ampacity
-Conductor Ampacity, wire size.
-table 301.15(B)(16).
Box Fill
-Sizing outlet box.
-Sizing Pull box.
Load calculation (Residential)
-Single family.
-Range and dryer’s calculation.
-Service \ Feeder Conductors.
Transformers
-Transformers Size.
-Transformers OCPD calculations.
-Transformers Short Circuit calculations.
-Delta-Wye transformers Calculations.
Motors calculations
-Motor OCPD calculations.
-Motor NEMA Starters calculation.
-Motor Locked Rotor Calculation.
Electrical schematics
- Delta-delta transformers.
- Delta-Wye transformers.
- Three way switch.
- Start/stop AC motor.
- 3 phase A.C. Motor Winding and Connections Wye
- 3 phase A.C. Motor Winding and Connections Delta
- Network cable wiring pin-out.
- Wye Start-Delta Run.
- Electrical Symbols
Burial Depth
-600v or less.
-Over 600v.
Grounding
-Equipment Grounding
-Grounding Electrode Conductor.
-Grounded Conductor, Main Bonding Jumper, System Bonding Jumper, and Supply-Side Bonding Jumper for Alternating-Current Systems.
NEMA Device Configurations.
-Plugs.
-Enclosures.
Electrical Calculations.
-Formula Wheel.
-Power Triangle.
-Series/Parallel.
NEC Tables section.
Color Code.
-Resistors color code.
-Phase wire color code.
-Panel color code.
NEC Calculations Examples.
-Bank load calculation.
-Store load calculation.
-Scholl load calculation.
-Multi-family dwelling load calculation.
-Office building load calculation.
-Restaurant load calculation.
-Motor I load calculation.
-Motor II load calculation.
-Ranges load calculation.
2014 NEC Code Changes.
Units Converter.
- Temperature.
- Energy.
- Length.
- AWG to millimeter.
- Watts to Lumens.
- Torque.
NFPA 70E Table 130.7 (C) (16).
Arc Flash Calculation.
- NFPA 70E Table 130.7 (C) (15)(a).
Torque Specs for lugs and bolts.
- Squared D.
- GE.
-more coming soon.
release version history:
(1.2.6.15) Dec 14, 2015
(1.2.4.2.5) Feb 5, 2013
National Electrical Code and "NEC" are registered trademarks of the NFPA
-And more coming soon! Stay tuned for updates.
If you like to report bugs or suggestions, please send them to <a href="mailto:electricianbible@gmail.com">electricianbible@gmail.com</a>
</div> <div jsname="WJz9Hc" style="display:none">Um deve ter utilidade para eletricista de fornecedores de eletricidade, ou aqueles que procuram passar uma certificação elétrica.
Cálculos por National Electric Code 2014.
Cálculos incluídos:
Queda de voltagem
Queda de tensão Condutores de -circuit.
-Minimum Tamanho do condutor.
Tubulação da curvatura
-Offset.
Selas curvatura -Três.
-Rolling Offset
-detail Suporte Conduit.
Flexão -Segment.
Cálculos Raceway.
Cálculo do tamanho -Raceway.
Cálculo -Raceway
Número de -Maximum mesmos fios de tamanho
-Conduit Support \ n-condutores Suporte
Espaçamento -Conduit
Aplicações -Conductor e Insulations
-Cabo Cálculo Tray
-Metric Designators Trade Tamanho.
-R90, RW75, TWN75, T90, TW, TW75, TWU, TWU75
Ampacity
-Conductor Ampacity, tamanho do fio.
-table 301,15 (B) (16).
Box Fill
Caixa de saída -Sizing.
-Sizing Caixa Pull.
Cálculo da carga (Residencial)
-Família única.
-range E cálculo do secador.
-Serviço \ Condutores de alimentação.
Transformadores
Tamanho -Transformers.
Cálculos -Transformers OCPD.
-Transformers Cálculos de curto circuito.
-delta-Wye transformadores cálculos.
Cálculos Motors
Cálculos -veículos OCPD.
Cálculo -veículos NEMA Starters.
-veículos Locked Rotor Cálculo.
Esquemas elétricos
- Transformadores Delta-delta.
- Transformadores delta-estrela.
- Interruptor de três vias.
- Iniciar / parar motor AC.
- 3 fases de corrente alterna Motor de enrolamento e conexões Wye
- 3 fases AC Motor enrolamento e conexões Delta
- Cabeamento de rede pin-out.
- Start-Wye Delta Run.
- Símbolos elétricos
Profundidade Burial
-600v Ou menos.
-Mais De 600v.
Aterramento
Aterramento -Equipamento
Eletrodo de aterramento do condutor.
-Grounded Conductor, Main Bonding Jumper, sistema de ligação Jumper, e do lado da oferta Bonding Jumper para corrente alternada Systems.
NEMA configurações do dispositivo.
-Plugs.
-Enclosures.
Cálculos elétricos.
-Fórmula Wheel.
Triângulo -Power.
-series / Paralela.
Seção Tabelas NEC.
Código de cores.
-Resistors Código de cores.
-fase Código de cor.
Código de cor -Panel.
NEC Cálculos exemplos.
Cálculo da carga -Bank.
Cálculo da carga -Store.
Cálculo da carga -Scholl.
Cálculo da carga habitação -Multi-família.
-Office Cálculo da carga edifício.
Cálculo da carga -Restaurant.
-veículos Eu carregar cálculo.
-veículos II cálculo da carga.
Cálculo da carga -Ranges.
2014 Alterações no código NEC.
Unidades Converter.
- Temperatura.
- Energia.
- Comprimento.
- AWG para milímetro.
- Watts para lúmens.
- Torque.
NFPA 70E Tabela 130,7 (C) (16).
Cálculo Arc Flash.
- NFPA 70E Tabela 130,7 (C) (15) (a).
Especificações de torque para lugs e parafusos.
- Squared D.
- GE.
-mais em breve.
liberar histórico de versão:
(1.2.6.15) 14 de dezembro de 2015
(1.2.4.2.5) 5 de fevereiro de 2013
Código Elétrico Nacional e "NEC" são marcas registradas da NFPA
-E Mais em breve! Fique atento às atualizações.
Se você gosta de relatar bugs ou sugestões, por favor, enviá-los para <a href="mailto:electricianbible@gmail.com">electricianbible@gmail.com</a></div> <div class="show-more-end">